Início
Quem Somos
Produtos
Baixar
Biblioteca Técnica
Contato
Interrogação
Mapa do Site
Ligações
 

Alarme & cabo Audio & Eletrônico

Belden Equivalente Cabos

Cabos coaxiais

Controle Cabos

Cabos de Fibra Óptica

Cabos Flexíveis

Instrumentação Cabos

Lan Cabos
Cabos de energia
Ferroviária Cabos

Robótica

Material Circulante Cabos
Rubber & Crane Cabos
Cabos de Segurança

Telefone Cabos

Aeroporto Cabos

Cabos Bus

Bucins

Data Cabos

Calor Detecção Cabos
High Temperature Cabos
Highway Cabos
Marine, Petróleo, Gás e Petroquímica Cabos
Cabos Especiais
Cabos espiraloidais
Termopar Cabos
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Telefone Cabos

 PVC Insulated Jumper Wires to IEC 60189-1

Aplicativo

The jumper wires are used for interconnection between terminal blocks at main distribution frames (MDF), cross connection cabinets (CCP) and distribution frames or boxes.

Normas

• IEC 60189-1

• IEC 60332-1

• UL1581 Sec.VW-1

Construção

Condutores
Solid annealed tinned copper 0.5/0.6/0.8mm as per IEC 60228 Class 1

Isolamento
PVC

Twisted Pairs
Insulated conductors are twisted into pairs with varying lays to minimize crosstalk

Electrical & Propriedades Mecânicas

Nominal Conductor Diameter

mm

0.5

0.6

0.8

Conductor Size

mm2

0.196 0.283

0.5

Maximum Conductor Resistance @20°C

Ω/km

98 66

35

Minimum Insulation Resistance @500V DC

MΩ.km

50 50

50

Nominal Insulation Thickness

mm

0.225 0.225

0.275

Nominal Insulated Conductor Diameter

mm

0.95 1.05

1.35

Mechanical and Thermal Properties

Temperature range during operation (fixed state): -30°C – +70°C
Temperature range during installation (mobile state): -20°C – +50°C
Minimum bending radius: 7.5 x Overall Diameter

Color Code

Standard colour code is per IEC 60189-1

Dimensões e Peso

Cabo Código

Número de Fios

Espessura nominal de isolamento mm

Diâmetro máximo global
mm

Peso nominal kg/km

0.5mm Conductor, 0.95mm Insulated Wire
TC189-Y-1W05 1 0.225 1.25

2.5

TC189-Y-2W05 2 0.225 1.95

5.0

TC189-Y-3W05 3 0.225 2.25

7.5

TC189-Y-4W05 4 0.225 2.40

10.0

TC189-Y-5W05 5 0.225 2.60

12.5

0.6mm Conductor, 1.05mm Insulated Wire
TC189-Y-1W06 1 0.225 1.45

3.0

TC189-Y-2W06 2 0.225 2.15

6.0

TC189-Y-3W06 3 0.225 3.0

9.0

TC189-Y-4W06 4 0.225 3.4

12.0

0.8mm Conductor, 1.35mm Insulated Wire
TC189-Y-1W08 1 0.275 2.05

5.8

TC189-Y-2W08 2 0.275 2.75

11.6

TC189-Y-3W08 3 0.275 3.7

17.4

TC189-Y-4W08 4 0.275 4.2

23.2